Easi-Screed Standard

Easi-Screed Standard
Self levelling cementitious floor screed system – may be applied 2-20mm thick in one layer
  • Self levelling screed producing a smooth, dust-free finish
  • Excellent for smoothing out worn or ridged (old or new) concrete
  • Ideal for all domestic/commercial uses
  • Accepts foot traffic in only 3-4 hrs

Quantity Calculator

Easi-Screed Standard
25 kg

£53.90
  • Buy 5 for £50.60 each
  • Buy 20 for £47.75 each
  • Buy 50 for £43.50 each
  • Buy 100 for £39.75 each

You may also need

Price for all selected : £0.00
  1.    This itemEasi-Screed Standard

Request Quote
Or call: 0800 980 0852 / 01234 846400

Details

Details

Easi-Screed Standard has been formulated to answer many requests for a commercial grade, light industrial or heavy domestic self levelling screed. It has an extremely fast cure accepting foot traffic after 3-4 hrs and overlayments/carpets after only 12-24 hrs.

Easi-Screed Standard can be laid from only 2mm-20mm thick in a single layer, has excellent adhesion and is non-toxic and non-taint.

Should it be applied in industrial application, we strongly advise it is coated with an epoxy such as Flortex SG or Flortex Professional to provide an impervious, hard wearing surface.

  • Cures to a strong 36N/mm2
  • Self levelling screed producing a smooth, dust-free finish
  • Excellent for smoothing out worn or ridged (old or new) concrete
  • Ideal for all domestic/commercial uses
  • Accepts foot traffic in only 3-4 hrs
  • Allow 12-24 hrs to cure before covering with carpets, tiles or paint
  • May be applied from 2-20mm thick in one layer
  • Very easy application that requires no expensive professional labour
Specifications

Specification

Pot life:20-30 mins @ 20oC
Application temperature:5oC - 25oC
Application:Trowel or Pump
Curing Time:Initial curing: 2-3 hours
To accept floor coverings: 12-24 hours
Number of parts supplied:1
Priming required:Yes - use Easiscreed Primer

Please consult the technical data sheet for full technical product data.

View FileEasi-Fließestrich Standard Technisches Datenblatt    Size: (215.45 KB) View FileEasi-Screed Standard Technical Data Sheet    Size: (319.38 KB) View FileEasi-Screed Standard Safety Data Sheet    Size: (118.52 KB)
Application

Application

Preparation:
Thorough substrate preparation is essential.
The surface should be clean, sound and free from all loose particles such as old adhesive residues, dust, plaster spillages, grease, paint, polish and any other compound, which may become softened by the introduction of water or be detrimental to the required bond. All laitance should be removed by mechanical means such as shot-blasting or scrabbling, to ensure a sound sub-base suitable to receive the screed.
Concrete bases and screeds must be fully cured and firm. Surface hardeners and curing membranes must be removed prior to screeding.
Sub-floors must conform to the dryness requirements of BS8203 1987 and must incorporate an effective damp proof membrane. Relative humidity should be less than 75%. The screed may be applied onto a suitable surface damp proof membrane where a good mechanical key has been provided. This may be achieved by applying dry silica sand to the second coat of DPM whist it is still wet. Single part screed is not impermeable to water and should not be used when damp conditions prevail.
Underfloor heating must be switched off at least 48 hours before and after application. Temperature should then be increased by 5oC, at 24 hour intervals.


Priming:
Concrete or sand and cement screeds – prime with Polycote Easi-Screed Primer.
Non-absorbent surfaces – prime with Polycote WD Primer.
Oily/contaminated surfaces - prime with Polycote OT Primer
Damaged DPM / Rising damp issues - prime with Polycote DPM Primer
Please refer to relevant Data Sheets for preparation and priming methods.


Mixing:
 Measure 5L of clean water into a suitable sized bucket.
Gradually add the entire 25kg quantity of powder whilst mixing with a heavy duty slow speed drill and mixing paddle. Mixing by hand does not readily give a thoroughly or evenly mixed product.
Mix for at least one minute to allow the additives to dissolve and produce a homogenous mix which should be lump free and a consistency of single cream. When mixed allow to stand for 2 minutes and stir again before application..
Do not mix more than can be applied in 25 minutes. Do not add excess water.

Application:
 Starting at the furthest corner from the exit pour the material evenly onto the floor to the required thickness and allow the material to start levelling.
The use of depth adjustable floats or a pinned/notched leveller is recommended to assist in spreading the screed to a constant thickness.
A spiked roller should be used immediately over the freshly poured material to eliminate any bubbles trapped within the screed. The next mix of material must be rapidly produced and poured along the wet edge of the material as well as across the exposed floor.
Each application should be laid within 20 minutes of the area adjoining in order to blend evenly into the edge of the previously laid material. This can be helped by gently trowelling along the joint.
Once the workable time has been exceeded it is not possible for the new material to be blended into previously applied material. Therefore the floor topping should be applied to the entire area in one continuous operation.

Application by pump:
 Prior to laying the mixed compound carry out a flow test using a flow ring (30mm diameter x 50mm long). A flow diameter of 135mm + or – 10mm should be achieved, adjust mix accordingly to comply to this flow criteria. Periodically check to ensure mix remains in limit.

Warning:
 1) If the product is not spike rolled immediately and the screed begin to cure, roller spike marks will remain visible. 2) Failure to disperse the air bubbles by spike rolling may result in a lesser impervious finish.
3) Do not add excess water

Q&A

Product Questions

I have a garage that is 10 mtrs x 5 mtrs and the floor is becoming very potmarked and is very dusty - will this help to level/seal the floor and is it suitable for use in a garage? How much will I need for my garage?
-3
Question by: Linda on 17 Aug 2015 12:15:00
Yes this will help, for your area you will require 10 units.
If you give one of our technical team a call on free phone 0800 980 0852 and we will run through the job and what you will have to do.
Answer by: Guy Stanton (Admin) on 4 Mar 2016 07:54:00
-19
You must be logged in to answer questions.

Customer Reviews

Login, and be the first to review this product

Add a Review

Other Products You May Need

  • Mixing Paddles

    Mixing Paddles

    £18.90
    For thorough and effective mixing of two-part products.
  • Spiked Shoes – Pair

    Spiked Shoes – Pair

    £38.95
    Pair of spiked shoes for use with wet coatings and screeds
  • Spiked Roller

    Spiked Roller

    £44.95
    For spike rolling any of our Cretex or Flortex Screeds such as Easi-screed and Flortex PU Screed. Effectively removes air bubbles.
  • Pin Leveller

    Pin Leveller

    £78.50
    600mm pin leveller for screeding

Please wait...

Product Successfully Added to Your Cart